Full text available in Adobe Acrobat format:
http://www.architectura.actapol.net/volume10/issue1/10_1_43.pdf
Issue 10 (1) 2011 pp. 43–50
Henryk Żelazny
THE RELATIVE AIR HUMIDITY IN THE BATHROOM DURING THE VARIOUS PROCESSES RELATED TO THE USE OF ROOM
Keywords: Keywords: relative humidity of air, bathroom, the use of rooms
Abstract: The aim of this study was to analyze the formation of relative humidity in the bathroom in the prefabricated reinforced concrete building during washing in the sink, a bath under the shower or in bathtub, laundry in a washing machine and drying clothes. Air relative humidity was evaluated with using the microclimate meter MM-01 with the set of probes suspended in a half of room’s height. The tested hygrometric index rose the most (that is, up to 26%) during a bath under the shower and amounted 63.3%. This value, however, did not exceed the limit of 70%, which is conducive to reproduce difficult to eliminate molds.
For citation:
EndNote
BibTeX
RefMan
MLA | Żelazny, Henryk. "THE RELATIVE AIR HUMIDITY IN THE BATHROOM DURING THE VARIOUS PROCESSES RELATED TO THE USE OF ROOM." Acta Sci.Pol. Architectura 10.1 (2011): 43–50. |
APA | Żelazny H. (2011). THE RELATIVE AIR HUMIDITY IN THE BATHROOM DURING THE VARIOUS PROCESSES RELATED TO THE USE OF ROOM. Acta Sci.Pol. Architectura, 10 (1), 43–50 |
ISO 690 | Żelazny, Henryk. THE RELATIVE AIR HUMIDITY IN THE BATHROOM DURING THE VARIOUS PROCESSES RELATED TO THE USE OF ROOM. Acta Sci.Pol. Architectura, 2011, 10.1: 43–50. |
Streszczenie w języku polskim:
http://www.architectura.actapol.net/tom10/zeszyt1/abstrakt-43.html
http://www.architectura.actapol.net/tom10/zeszyt1/abstrakt-43.html